Ballymanaggin
Townland in the civil parish of Clondalkin, barony of Uppercross, Co. Dublin; in Irish Baile Mhic Cnagáin
- Area
- 57.6 ha
- 142 acres
- Land parcels
- 332
- registered freehold, median 390 m²
- Zoning
- C2.1
- EE
- Planning
- 100
- applications since 2010
Land parcels
Registered freehold land, Tailte Éireann
332 registered freehold parcels lie mostly in Ballymanaggin, from 1 m² to 63,531 m² (6.35 ha, 15.7 acres). The dashed line is the townland's boundary; 32 neighbouring parcels touch it.
Download the townland: DXF, in Irish Transverse Mercator metres, with its boundary, parcels and buildings; GeoJSON or KML.
Zoning
Development plans, national zoning
- C2.1EE (Industrial, enterprise, employment)
South Dublin County Development Plan 2022-2028, South Dublin · 247 parcels The zoning objective in the plan - R2RES (Existing residential)
South Dublin County Development Plan 2022-2028, South Dublin · 63 parcels The zoning objective in the plan - R3Z14: Strategic Development and Regeneration Areas (SDRAs) (Residential, mixed residential and other uses)
Development Plan 2022-2028, Dublin · 2 parcels The zoning objective in the plan - G1OS (Open space, park)
South Dublin County Development Plan 2022-2028, South Dublin · 0 parcels The zoning objective in the plan
Source: Tailte Éireann and the Department of Housing (MyPlan), national zoning, CC BY 4.0.
Planning applications
Sites that touch the townland, newest first
7 Jul 2026Declared not exempt
Use of existing unit in its current form as a Gym; no alterations proposed.
Declaration of exemption sect. 5 · South Dublin County Council, ED26/0062
11 Jun 2026Request additional information
Retention for change of use from commercial enterprise unit to community social club with after school homework club, breakfast club and associated community uses with administrative offices; Permission for proposed internal alterations.
Permission and retention · South Dublin County Council, SD26A/0137W
15 May 2026Refuse permission
370sqm side and rear extension, new entrance, and new facade to front elevation.
Permission · South Dublin County Council, SD26A/0067W
27 Apr 2026Grant extension of duration of permission
Provision of 4 new information and communications technology (ICT) Facility buildings and associated development at the subject site, superseding elements of the extant planning permissions on site (Reg. Ref.: SD18A/0068 and Reg, Ref.: SD19A/0185). The application site is subject to an EPA Industrial Emissions Licence (Ref. No,: P1113-01) relating to the Energy Centre permitted on site, The single storey Energy Centre, gas pressure reduction station, and 110kV Gas Insulated Switchgear (GIS) substation permitted under Reg, Ref.: SD18AI0068 and Reg. Ref.: SD19AI0185 will be constructed as previously approved and are not affected by the current application. The proposed development will comprise the following: The construction of 4 ICT Facility buildings (ICT Facilities 1, 2, 3, and 4) with a combined total gross floor area {GFA) of c. 47,564.5 sq.m, Each ICT Facility building includes associated external plant areas, totalling c, 20,649.5 sq,m, ICT Facilities 1, 2, and 3 will be located in the eastern portion of the site, and each comprise a GFA of c. 15,196 sq.m (including ancillary office and administration space) over part two and part three levels with a maximum height of c, 25 metres and a parapet height of c, 19.5 metres, Each of the ICT Facilities will include an associated external plant area of c, 6,624 sq,m, ICT Facility 4 will be located in the southern portion of the site and comprises a GFA of c, 1,976.5 sq,m (including ancillary office and administration space) over two levels with a maximum height of c, 15 metres and a parapet height of c. 10.5 metres, This ICT Facility includes an associated external plant area of c. 777.5sq.m, Each ICT Facility building will accommodate ICT equipment halls, associated electrical and mechanical plant rooms, loading bays, maintenance and storage space, office administration areas, and screened plant. Construction of internal road network and circulation areas, footpaths, provision of 153 no. car parking spaces and 54 no, cycle parking spaces. Connections to vehicular access routes, roads, services and permitted infrastructure relating to the Energy Centre and 110kV GIS substation permitted under Reg, Ref.: SD18A/0068 and Reg, Ref.: SD19A/0185. Provision of emergency generators with associated flues, water storage tanks and associated pump rooms (comprising 150 sq,m in total) to serve each of the proposed ICT Facility Buildings. Hard and soft landscaping and planting, lighting, and all associated works, including underground foul and storm water drainage network, boundary treatments and security fencing, attenuation areas, and utility cables.
Extension of duration of permission · South Dublin County Council, SD20A/0309/EP
8 Jan 2026Grant permission & grant retention
The proposed development includes retention permission for the reorientation of the gas AGI (above-ground installation) compound permitted under SDCC Reg. Ref.: SD23A/0158 and to retain an existing Gas AGI skid located to the north of the gas AGI compound. The development also includes the retention and completion of an extension to the existing Gas AGI compound to the south, to provide for a pressure regulating and metering station (PRMS) compound area. The PRMS compound extension comprises the following buildings and gas related infrastructure:•Skid House structure with a total area of c. 118 sq.m and overall height of c.3m. •E&I Kiosk with a total area of c. 11 sq.m and overall height of c. 2.7m •Boiler House comprising 2 no. individual units (Boiler House 1 & Boiler House 2) both with an area of c. 22 sq.m and overall height of c.3m. •Gas Quality Building with a total area of c. 3 sq.m and overall height of c. 2.4.m • All associated and ancillary works including valves and pipework, site lighting, boundary treatments, landscaping, drainage and infrastructure. The proposed development is located within a site which is subject to an EPA Industrial Emissions (IE) Directive license.
Permission and retention · South Dublin County Council, SD26A/0004W
19 Dec 2025Grant extension of duration of permission
Installation of an above ground water retention tank (13.1m x 8.1m x 2.85m high); underground water retention tank (8.3m x 3.70m x 5m deep) and balancing system, located at the south-east corner of the site including the diversion of surface water drains to the existing foul sewer system via the proposed tank and all site works associated with the proposed development.
Extension of duration of permission · South Dublin County Council, SD19A/0332/EP
8 Oct 2025Invalidate application
370sqm side and rear extension, new entrance, and new façade to front elevation.
Permission · South Dublin County Council, SD25A/0254W
18 Aug 2025Grant permission for retention
Retention Permission for several items further to the construction of the development as granted planning under South Dublin County Council Reg. Ref. SD24A/0015 for an extension, refurbishment, and alterations to adjoined warehousing Units 1, 2 & 3 Cloverhill Industrial Estate, Clondalkin, Dublin 22. The items for which Retention Permission is sought are as follows: 1.Alterations at Unit 1, resulting in a total area of 10,153m2 (10,120m2 of warehouse area, and 33m2 of Staff Facilities Area) as follows: A.Omission of previously proposed subdivision of Unit 1 in two units (Unit 1A and Unit 1B), with no area change. B.Change of use of 276m2 of Ancillary Office Area and 236m2 of Staff Facilities Area to Warehouse Area (at Ground Floor) and removal of 545m2 of Ancillary Office and Staff Facilities Area (at First Floor) due to the omission of previously proposed 2 storey Ancillary Office for Unit 1A and Unit 1B and redesign of existing Plant Room area at North-western corner of Unit 1 to accommodate warehouse toilet block and IT room. 2.Alterations at Unit 3: change of use of 3m2 of Staff Facilities Area to Ancillary Office Area and 39m2 of Ancillary Office Area to Warehouse Area (at Ground Floor) and 3m2 of Ancillary Office Area to Staff Facilities Area (at First Floor), resulting in 5,182m2 (4,824m2 of warehouse area, 221m2 of Ancillary Office Area and 137m2 of Staff Facilities Area) due to the structural design arrangements at the Ancillary Office and demolition of 2No. existing warehouse offices. 3.Previously proposed existing internal roller door to be built up, now retained to provide a connection between Unit 1 and Unit 3. 4. Elevational changes, with no floor area changes, due to the above mentioned modifications, including: A.Addition of 3No. fire escape concrete steps and refugee area at Unit 1. B.Omission of 2No. personal doors at Unit 1. C.Relocation of 1No. level entry door at Unit 1 and, D.Omission of 1 dock leveller door due to the retention of existing level door and personnel door at Unit 3. 5.Associated site works including: A.Existing ancillary area at front elevation of Unit 1 is retained unaltered. B.Previously proposed HGV access at front elevation of Unit 1 now omitted due to the omission of the subdivision on Unit 1, HGV access is now at South-eastern corner of the site. C.Addition of fence and swinging gate for fire escape circulation at South-western corner of Unit 1 and omission of fire tender swinging gate at the rear of the site, between Unit 1 and Unit 3. D.Site works adjustments due to elevational changes. All other elements remain as per granted planning application Reg. Ref. SD24A/0015.
Retention · South Dublin County Council, SD25A/0191W
30 Jan 2025Grant permission
The development will consist of the construction of an extension of c.650 sq.m to an existing industrial unit and all associated site development works. The proposed extension shall be used for storage of dry mixed recyclable waste prior to shipping.
Permission · South Dublin County Council, SD25A/0016W
21 Aug 2024Refuse permission
The development proposed will supersede the permitted ICT Facility 4 under Reg. Ref.: SD20A/0309, as previously amended under Reg. Ref.: SD22A/0093 and Reg. Ref.: SD23A/0158. A five-year planning permission is sought in respect of this proposed development. The proposed development comprises the following: • Construction of an ICT Facility Building (ICT Facility 4), with a Gross Floor Area (GFA) of 15,744 sq.m and a parapet height of c. 21.80m (with flues located at roof level, c. 4.5m over parapet height), over 3 no. levels, located in the southern portion of the wider landholding. This ICT Facility includes an associated external plant area of c. 1,796 sq.m over two levels, accommodating 22 no. emergency generators and associated flues. • The ICT Facility building will accommodate ICT equipment halls, associated electrical and mechanical plant rooms, loading bays, maintenance and storage space, office administration areas and screened plant. • Construction of ancillary structures including a guard hut, fire hydrant water storage tanks, fire hydrant pump plantroom, water mist fire protection pump plantroom and water tanks, and cold water plantroom to the west of the proposed ICT Facility 4. • Construction of a revised internal road network and circulation areas to serve ICT Facility 4, footpaths, provision of 25 no. car parking spaces (including 2 no. disabled parking bays) and 18 no. cycle parking spaces within a bike shelter. • Lighting, boundary treatments and all ancillary and associated development (including the construction of an underground foul and storm water drainage network, and utility cables). • Hard and soft landscaping and planting, lighting, screening, and all associated works, including underground foul and storm water drainage network, boundary treatments and security fencing, attenuation areas, and utility cables. An EPA-Industrial Emissions Directive (IE) licence will be required to facilitate the operation of the proposed development.
Permission · South Dublin County Council, SD24A/0201W
14 Jun 2024Grant permission for retention
We, Alucraft Ltd, make application to South Dublin County Council for permission. FOR RETENTION of development at this site address: Unit AF4O, Cloverhill Industrial Estate, Clondalkin, Dublin, D22 HY51, for alterations to permitted development under Reg. Ret: 91A/1082, 90A/734, 89A/50, 85A/505, T.A.562., R.A. 1123 and R.A. 1098, comprising of the following: 1. 1 No. 3-sided bike shelter with polycarbonate roof and wall sheets measuring 16.5 sq.m GFA to front of building, 2. 1 No. 3.83M High prefabricated structure comprising of additional office space measuring 76.8 sq.m GEA to front of building, 3. 1 No. 7.61M High, permanent storage enclosure with loading bay measuring 178.42 sq.m GEA to rear of building, 4. 1 No. 2.74M high prefabricated structure comprising of additional WC provision measuring 18.11 sq.m GFA to rear of building connected to existing foul sewer, 5. 1 No. 2.74M high prefabricated structure comprising of additional WC provision measuring 13.47 sq.m GFA to rear of building connected to existing foul sewer, 6. 1 No. 6.54M high permanent loading platform enclosure, measuring 100.95 sq.m GEA to rear of building, 7. 1 No. 3.31M (H) glazed curtain wall entrance porch/lobby to main reception measuring 9.11 sq.m GFA to front of building, 8. 1 No. 2.87M (H) glazed curtain wall entrance porch/lobby to main reception measuring 6.63 sq.m GFAto front of building, and all associated ancillary site works on an overall site area of 2.23 hectares.
Retention · South Dublin County Council, SD24A/0153
14 Jun 2024Grant permission & grant retention
Ecomondis Ireland Unlimited Company intend to apply for permission for retention of development and permission for development at Greyhound Recycling, Crag Avenue, Clondalkin Industrial Estate, Clondalkin, Dublin 22 The development to be retained consists of the constructed logistics office (c.74.5 sq.m), weighbridge office (c.40 sq.m), logistics ablution (c.28.5 sq.m), logistics canteen (c.23.75 sq.m), site canteen! laundry (c.42 sq.m), site ablution (c.40 sq.m), air handling plant featuring carbon stack of height c.16.6 metres (c. 335 sq.m), annexe building featuring chimney of height c.14 metres (c. 153 sq.m), rainwater tank (c. 7.0 sq.m) and generator room (c. 25.3 sq.m). Elements of the buildings for retention are associated with permitted development on site (SD03A/0838 and SD06A/0404) that require a waste license from the regulatory authority. The development proposed consists of the construction of 1 no. new service garage building c. 11.60 metres in height with a gross floor area of c. 636 sq.m and all associated site development works above and below ground necessary to facilitate the proposed development on this site of c.4.476 ha.
Permission and retention · South Dublin County Council, SD24A/0073
17 May 2024Grant permission
Gabor Construction Limited are applying for Permission for partial change of use as constructed under Reg. Ref. S99A/0146, from Warehouse to Office use (29sqm) to include for internal alterations and extension of current office floor areas on ground and first floor level.
Permission · South Dublin County Council, SD24A/0125W
16 Apr 2024Grant permission & grant retention
Retention for ground floor rear Extension and permission for extension to first floor at rear and all ancillary site works
Permission and retention · South Dublin County Council, SD24B/0045
23 Jan 2024Grant permission
Extension, refurbishment, and alterations to adjoined warehousing Units 1, 2 & 3 Cloverhill Industrial Estate, Clondalkin, Dublin 22 as follows: 1. The existing warehousing Unit 1 (existing total area 11,725m2, comprised of 8,526m2 warehouse area and 3,199m2 of two storey ancillary offices) is proposed to be subdivided into two units as follows: A. Unit 1A, 2,582m2 in total including redesigned ancillary offices on 2 floors with an overall area of 522m2 (note: existing two storey office will be reduced by the demolition of 259m2 first floor offices and change of use of part of ground floor office, 281m2, to warehousing space), with a resulting warehouse area of 2,060m2. B. Unit 1B, 8,116m2 in total including redesigned ancillary offices on 2 floors with an overall area of 568m2 (note: existing two storey office will be reduced by demolition of 768m2 first floor offices and change of use of part of ground floor office, 801m2, to warehousing space) with a resulting warehouse area of 7,548m2. Both of the above units to receive front/southern elevation upgrades and access improvements of HGV's entering the site through two improved existing entrance/exit locations, addition of 1 no. goods door to Unit 1A, addition of 4 no. dock leveller doors & 1 no. goods door to Unit 1B, removal of a disused sprinkler pumphouse/plant room & (167m2) and sprinkler tank (24m2, 7m high) to the rear of Unit 1B, associated elevational changes, drainage works including surface water swales, landscaping, rearranged car parking, provision of cycle parking and associated site development works. 2. Existing Unit 2 building area remains unaltered. 3. Existing Unit 3 with a total area of 4,995m2, proposed alterations will include existing warehouse office area (90sqm total over 3 locations) to be reduced to 42sqm by the demolition of 24m2 of first floor office and the change of use of 24sqm of part of ground floor office area to the warehousing area, and separately demolition of 147sqm of adjoined warehouse corridor resulting in 4,782m2 of warehouse area with the addition of a proposed new two storey adjoined ancillary office area extension of 358m2, with associated elevation works, ancillary cycle parking and adjusted car parking, addition of 2no. dock leveller doors & 1 no. goods door to the side/eastern elevation plus associated drainage works including surface water swales, landscaping and associated site development works.
Permission · South Dublin County Council, SD24A/0015
12 Jul 2023Grant permission
Alterations to the development permitted under Reg. Ref.: SD18A/0068, as previously amended under Reg. Ref.: SD19A/0185 and Reg. Ref.: SD20A/0242, and to the development permitted under Reg. Ref.: SD20A/0309, as previously amended under Reg. Ref.: SD22A/0093. The proposed alterations in summary comprise the provision of an altered energy centre design and all associated development, along with minor alterations to the permitted site layout, provision of a gas AGI, and all ancillary works. The development, for which a 5-year planning permission is sought, will comprise the following: Construction of a revised energy centre in the western part of the subject site, to accommodate alternate generation technology, including 10 no. gas generation turbines (all with associated flues, 8 no. c. 33 metres (m) in height and 2 no. c. 15 m in height), 2 no. steam turbines including 2 no. steam turbine generator enclosure buildings with a gross floor area (GFA) of 219 sq.m each and a height of c. 6.2 m, associated steam turbine generator distribution and control structure with a GFA of 84 sq.m and an overall height of c. 4.2 m, and 2 no. steam turbine / air cooled condenser structures with a height of c. 25.4 m. Construction of 8 no. 33/20kV transformer bays to the southeast of the energy centre, with a further 12 no. gas / steam transformers to serve the proposed turbines to the west of the energy centre. Provision of 3 no. 13.6 m high fuel storage tanks, a fuel oil enclosure building (with a GFA of 50 sq.m and an overall height of c. 3.8m), a fire pump enclosure building (with a GFA of 65 sq.m and an overall height of c. 3.2 m) along with 3 no. c. 14.1 m high sprinkler tanks, a c. 14.5 m high water tank, and a water treatment plant building (with a GFA of 218 sq.m and a maximum height of c. 17 m including rooftop plant). Provision of 6 no. black-start / emergency generators to the south of the energy centre with an overall height of c. 5 m; Provision of a single storey over basement level powertrunk building (with a GFA of 932 sq.m and an overall height of c. 4.1 m) to the southeast of the proposed energy centre. Provision of a 3-storey over basement medium voltage / low voltage building (with a GFA of 3,161 sq.m and an overall height of c. 16.3 m) to the southwest of the proposed energy centre. Provision of 2 no. transformers adjacent to the substation constructed under Reg. Ref.: SD18A/0068, as amended by Reg. Ref.: SD19A/0185 (located to the southwest of the proposed energy centre). Provision of a guard hut with a GFA of 21 sq.m and with a height of c. 3.2m, to the west of the medium voltage / low voltage building. Provision of a Gas AGI (above-ground installation) to the southwest of the subject site within a fenced compound, accommodating a single storey control room building with a GFA of 10 sq.m and overall height of c. 3 m, a plant kiosk with a GFA of 17 sq.m and an overall height of c. 3 m, and a boiler house with a GFA of 13 sq.m and an overall height of c. 3m. Reorientation of permitted ICT Facility Building No. 4 to accommodate the revised energy centre layout (with no other change to this permitted building). Associated and ancillary alterations to the site layout relating to landscaping, parking (including 18 no. car parking spaces, and bicycle parking within a covered bicycle shelter to serve the energy centre) and roads layouts, lighting and services, boundary treatments, drainage, landscaping, and all associated and ancillary works. An Environmental Impact Assessment Report (EIAR) will be submitted to the Planning Authority with the planning application and the EIAR will be available for inspection or purchase at a fee not exceeding the reasonable cost of making a copy at the offices of the Planning Authority. An EPA-Industrial Emissions Directive (IE) licence will be applied for to facilitate the operation of the proposed development.
Permission · South Dublin County Council, SD23A/0158
13 Jul 2022Grant extension of duration of permission
4 2-storey, 3 bedroom houses including parking and related infrastructural works, alterations and widening of existing vehicular access gateway at the front of the site onto Crag Avenue within the curtilage of the Protected Structures at No's 6 & 7 Ballymanaggin Lane (RPS reference numbers are 117 & 121 respectively).
Extension of duration of permission, 4 homes · South Dublin County Council, SD17A/0186/EP
23 Jun 2022Grant permission
Amendments to the development permitted under Reg. Ref. SD20A/0309 comprising: alterations to permitted ICT Facility buildings 2 and 3, to include internal reconfiguration of the ICT equipment halls, associated electrical and mechanical plant rooms, loading bays, maintenance and storage space, office administration areas, and reconfiguration of screened plant; alterations to the external facades of permitted ICT Facility buildings 2 and 3 to include modification and reconfiguration of fenestration, louvers, loading bays, and access doors, along with an increase in height of 1.2 metres to main parapet level and reduction in the height of rooftop plant to not exceed the parapet height of the buildings, along with the omission of previously permitted flues and exhaust ducts at roof level; omission of emergency generators and associated flues from permitted ICT Facility buildings 2 and 3; The proposed amendments to ICT Facility buildings 2 and 3 result in an increase in their gross floor area (GFA) of 2,511sq.m for each building, resulting in an overall increase in the GFA of the two buildings of 5,022sq.m; Alterations to the water storage tanks serving the permitted ICT Facility buildings, including total increase of 268 sq.m GFA to the permitted pumprooms and a reduction in the scale of the associated water storage tanks. All associated and ancillary works; The application site is subject to an EPA Industrial Emissions Licence relating to the Energy Centre permitted on site (under Reg. Ref.: SD18A/0068 as amended by Reg. Ref.: SD19A/0185).
Permission · South Dublin County Council, SD22A/0093
22 Jun 2022Grant permission
Change of use of 464sq.m of warehouse mezzanine storage, approved under planning reference SD18A/0031, to office use, as well as associated and ancillary internal works, elevational changes and external ground works to facilitate this new use.
Permission · South Dublin County Council, SD22A/0060
23 May 2022Grant permission
Car wash & car wash plant room with water recycling system; re-location of the main ID sign and all associated structures, drainage and site development works.
Permission · South Dublin County Council, SD21A/0360
16 May 2022Grant permission for retention
Retention of existing self-service laundromat facility.
Retention · South Dublin County Council, SD22A/0142
6 Apr 2022Grant permission for retention
Retention permission and continuation of use of a former double height warehouse within their building as 426.6sq.m of office use, over two floors as well as all associated and ancillary elevation changes.
Retention · South Dublin County Council, SD22A/0033
19 Jan 2022Grant permission for retention
Change of use from haulage yard to filling station open to the public; additional diesel pumps; palisade fencing; illuminated and non-illuminated signage; all associated site and development works.
Retention · South Dublin County Council, SD21A/0149
11 Jan 2022Grant permission
Construction of 2 two and a half storey, three-bedroom terrace houses and associated site works attached to the existing two and a half storey house at No. 6 Station Grove which was constructed in 2006; the 2 houses will complete this partially finished housing development which was originally granted permission under planning reference SD05A/0125.
Permission, 2 homes · South Dublin County Council, SD21A/0121
2 Nov 2021Grant permission
Full demolition of existing two storey 463sq.m building to make way for future development, subject to future separate planning application.
Permission · South Dublin County Council, SD21A/0185
The 25 most recent of over 100 applications.
Source: National Planning Applications, Department of Housing, Local Government and Heritage, CC BY 4.0. Applicants are not shown.
Nature and heritage
Designated sites and recorded monuments
Designated sites
- Proposed Natural Heritage Area: Grand Canal 002104
Recorded monuments
No recorded monument lies in the townland of Ballymanaggin.
Architectural heritage
- 9th Lock, lock, 1750–1770 · Regional interest
Description
Two-stage canal lock, c.1780, with coursed limestone walls having limestone coping. Three sets of timber and iron lock gates. Timber mooring post at intervals between gates. Lowest gate altered to allow construction of modern bridge.
- House, 1900–1910 · Regional interest
Description
Semi-detached three-bay two-storey house, c.1905. uPVC casement windows set in snecked rock-faced granite ground floor and beige brick first floor walls. Ground floor windows have round-arched blind recesses above. Granite porch hood supported by granite corbels over central uPVC door. Pitched artificial slate roof with brick chimney stacks.
- House, 1900–1910 · Regional interest
Description
Semi-detached three-bay two-storey house, c.1905. Timber casement windows set in snecked rock-faced granite ground floor and beige brick first floor walls. Ground floor widows have round-arched blind recesses above. Granite porch hood supported by granite corbels over a central replacement timber panelled door. Pitched artificial slate roof with brick chimney stacks. Modern brick extension to rere.
- House, 1900–1910 · Regional interest
Description
Semi-detached four-bay single-storey house, c.1905. uPVC casement windows set in snecked rock-faced granite walls. Beige brick to gables. Central window is segmental-arched. uPVC door set into projecting gable porch. Pitched artificial slate roof with brick chimney stacks.
- House, 1900–1910 · Regional interest
Description
Semi-detached four-bay single-storey house, c.1905. uPVC casement windows set in snecked rock-faced granite walls. Beige brick to gables. Central window is segmental-arched. Timber tongue and groove door set into projecting gable porch. Pitched artificial slate roof with brick chimney stacks. Iron railings and gate to street.
- House, 1900–1910 · Regional interest
Description
Semi-detached three-bay two-storey house, c.1905. Timber sash windows set in snecked rock-faced granite ground floor and beige brick first floor walls. Brick dressings to ground floor windows with round-arched blind recesses above. Granite porch hood supported by granite corbels over a central glazed timber panelled door. Pitched slate roof with brick chimney stacks. Iron railings and gate to street.
- House, 1900–1910 · Regional interest
Description
Semi-detached three-bay two-storey house, c.1905. Timber casement windows set in snecked rock-faced granite ground floor and beige brick first floor walls. Brick dressings to ground floor windows with round-arched blind recesses above. Granite porch hood supported on granite corbels over central glazed uPVC door. Pitched artificial slate roof with brick chimney stacks. Modern extensions to rere.
- House, 1900–1910 · Regional interest
Description
Semi-detached four-bay single-storey house, c.1905. Aluminium casement windows set in snecked rock-faced granite walls. Beige brick to gables. Central window is segmental-arched. Glazed aluminium door with fanlight set into projecting gable porch. Pitched artificial slate roof with brick chimney stacks. Iron railings and gate to street. Extension to rere.
- Anne's Brook Cottage, house, 1900–1910 · Regional interest
Description
Semi-detached four-bay single-storey house, c.1905. uPVC casement windows set in snecked rock-faced granite walls. Beige brick to gables. Central window is segmental-arched. uPVC door with fanlight set into projecting gable porch. Pitched artificial slate roof with brick chimney stacks. Extension to rere of property.
- House, 1890–1910 · Regional interest
Description
Semi-detached three-bay single-storey with dormer attic house, c.1900. Timber casement windows set in roughcast rendered walls with half-dormer window. Flat-roofed uPVC porch to entrance. Pitched artificial slate roof with central rendered chimney stack. Large modern extension to rere.
- House, 1890–1910 · Regional interest
Description
Semi-detached three-bay single-storey with dormer attic house, c.1900. Timber sash windows set in red brick ground floor walls with roughcast rendered first floor having half-dormer window. Timber panelled door with shallow projecting brick surround, flat concrete hood and simple timber fanlight. Pitched slate roof with central red brick chimney stack and raised gable coping. Lean-to extension to rere. Simple iron gate in modern street boundary wall.
- House, 1890–1910 · Regional interest
Description
Semi-detached three-bay single-storey with dormer attic house, c.1900. uPVC casement windows set in painted brick ground floor walls with roughcast rendered first floor having half-dormer window. Flat-roofed timber porch to entrance. Lean-to extension to rere. Pitched artificial slate roof with central red brick chimney stack.
- House, 1890–1910 · Regional interest
Description
Semi-detached three-bay single-storey with dormer attic house, c.1900. Aluminium casement windows set in roughcast rendered walls with half-dormer to first floor. Flat-roofed aluminium porch to entrance. Pitched artificial slate roof with central red brick chimney stack.
- House, 1900–1920 · Regional interest
Description
Detached three-bay single-storey house, c.1900, now derelict. Coursed granite rubble walls, half-timbered to gables, with red brick dressings to openings and quoins. Boarded-up window openings with granite sills. Projecting gable-fronted porch with semi-circular fanlight. Pitched artificial slate roof with central beige brick chimney stack.
- Bridge, 1850–1870 · Regional interest
Description
Single-arch road bridge over railway, c.1860. Three-centred arch with dressed voussoir stones. Coursed squared limestone parapets at road level raised with coursed granite rubble. Limestone rubble retaining walls either side of bridge.
Designated sites: National Parks and Wildlife Service. Recorded monuments: Sites and Monuments Record, National Monuments Service. Buildings: National Inventory of Architectural Heritage. Department of Housing, Local Government and Heritage, CC BY 4.0. Works at or in relation to a recorded monument need two months' written notice to the National Monuments Service (National Monuments (Amendment) Act 1994, section 12).
Ground and risks
Radon, landslides, flooding
- Radon
- About 1 in 20 homes in this area is likely to have high radon levels. Testing a home
- Landslides
- Susceptibility low, low (inferred), on the 1:50,000 map.
- Terrain model
- LiDAR of the Office of Public Works, flown in 2011, at 2 m: tile OPW_3086 (ZIP).
- Flooding
- The flood maps of the Office of Public Works: floodinfo.ie.
Radon Risk Map of Ireland, Environmental Protection Agency; Landslide Susceptibility Classification, Geological Survey Ireland; both CC BY 4.0. LiDAR: contains Irish Public Sector Data (Geological Survey Ireland & the Office of Public Works) licensed under a Creative Commons Attribution 4.0 International (CC BY 4.0) licence.
Homes sold
Property Price Register
No address of the register names Ballymanaggin with five sales or more. The sales of the area are on the page of Co. Dublin.
The townland
- Name
- Ballymanaggin · Baile Mhic Cnagáin
- Area
- 576,382 m² (57.64 ha, 142.43 acres)
- Civil parish
- Clondalkin, and its townlands
- Barony
- Uppercross
- Electoral division
- Clondalkin-Moorfield, the unit of the census
- Census 2022
- Clondalkin-Moorfield electoral division: 7,024 people in 2,283 households; 51% of households own their home; 20% of homes were built since 2001; 2% of dwellings stood vacant on census night, and 0% were holiday homes.
- Neighbouring townlands
- Cappagh, Clonburris Great, Clondalkin, Gallanstown, Neillstown, Raheen, Yellowmeadows
- Placenames
- Ballymanaggin on logainm.ie, the Placenames Database of Ireland
Townlands, civil parishes, baronies and electoral divisions, National Statutory Boundaries, Tailte Éireann, CC BY 4.0. Census 2022, Small Area Population Statistics by electoral division, Central Statistics Office, CC BY 4.0. A townland is the smallest land division of Ireland, and the unit of a rural address; old registers such as the 1901 and 1911 censuses file it under its civil parish and barony.